Certification of test results.
Blower door test results form.
Testing shall be performed at any.
Test results and sample test forms basic airtightness test results airtightness test results can be presented in a number of standardized formats.
Air leakage at 50 pascals cfm50 cfm50 is the airflow in cubic feet per minute from the blower door fan needed to create a change in building pressure of 50 pascals 0 2 inches of water column.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in climate zones 1 and 2 and 3 air changes per hour in climate zones 3 through 8.
Where required by the code official testing shall be conducted by an approved third party.
Testing shall be conducted with a blower door at a pressure of 0 2 inches w g.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
Understanding blower door test results.
Simply put a blower door is a diagnostic tool used to measure how much air infiltration air leakage occurs in a house.
Where required by the code official testing shall be conducted by an approved third party.
The following will help you conduct your.
Blower door tests are performed by trained and certified energy auditors but a homeowner can conduct a mini test to help pinpoint leaky areas of the home.